ctscan.jpg (12268 bytes)

General Electric Lightspeed 16 - Year 2003. Multislice 16, Ceramic Detector 16 X 912, Slice Thickness .625 to 10mm; 0.5 Second Scan, Performex 6.3 mHu Tube, 53kW Generator, Reconstruction time of 0.5 Second per Image; Silicon Graphics Octane Computer, DICOM, 73gb Hard Disk, System Software and Manuals.

GE CT MODEL LIGHTSPEED PLUS- QUADSLICE WITH H2 GANTRY - Year 2000. 0.5 Second Rotation; 7.8 Million Revolutions +/-. X-Ray tube with approximately 20 to 30 million mAs by the time CT is removed mid- October. Tube MX200CT2, Software Version 2.4.2H2, DICOM, Connect Pro, Direct 3D, Barcode Reading, SMART pre, SMART speed, System Software, Manuals and Phantoms.

GE CT LIGHTSPEED ULTRA - 8-SLICE/ MULTISLICE - Year 2003. Please call for more information as system will become available soon.

GE MODEL LIGHTSPEED QX1 - QUAD SLICE - Year 2000. With H1 Gantry, 4-Slice, 1 Console with Dual Monitors just like Cti, 6.3 Performex Tube installed in May 2003. Tube with 84,806,775 total tube mass, Gantry with 10 million rotations. High resolution chest option,  SMART prep, CT profusion kit, Octane computer with version 6U, 4.5A, 6.8A, 10, Cardiac Gating Monitor, Optical Disk, DICOM Compatible

GE CT SCANNER MODEL PROSPEED - Year 1998. I Series. Spiral/Helical. 1-Second CT Scanner. With: Xenon Detectors, 1 Console, 1 Patient Table, 1 Gantry and PDU. X-Ray Tube 55,000 slices +/-and gantry with 35 million +/-. Software Version 6.03.

GE CT MODEL PROSPEED “I” SERIES - Year 1995. Spiral/Helical 1 Second CT Scanner. X-Ray  tube with +/- 25,000 slices new in 2002. Gantry rotations 2.8 million. Options include 3D imaging, Optical disk, Software 6.03 Version.

GE HI-SPEED CT SCANNER 2X - Year 1995. Spiral/Helical 0.6 Partial Scan and 1-Second Full Scan. FAST Throughput CT; X-Ray tube with 112,000 slices, Gantry Rotations 6.069 million. Genesys operator’s console; Sun Microsystems computer; 48k Generator.

G.E. HI-SPEED NX/I – Year 2002. Compact High Speed Gantry – New Style. Single Slice. Solid-State Detectors, DICOM.

G.E. HI-SPEED LX/I – Year 1997. Spiral. Octane Computer, MPR, 3D, Smart Prep, DICOM, Advantage Workstation 1.2, Solid State Detectors, 110K Slices on MX 165 3.5M.H.U xray Tube, 850,050 Exposures on the Gantry, 1Second Scanning Metaless Cradle.

GE CT SCANNER MODEL CTi PERFORMEX - Originally a HighSpeed from 1995 and upgraded in June 2000 to CTi Performex. Performex tube with 812,394, Version 6.1 Software. Rotation count around 10 million, Octane computer, SMART Prep, SMART Ma, smart View, 0.8 Second option, 48 kW power generator, CT fluoro.

GE CT MODEL HISPEED ADVANTAGE RP 2X – Year 1995. Gantry: 11,433,346 rotations; Tube: 40,000 slices in May 2004, GE MX 165 CT tube; Hilight Detectors, HSA PDU, Single Console, GE HSA CT processor, 840 MB hard disk, HP 35470 4 mm DAT.

GE CT MODEL CTI PERFORMEX – Year 1999. Gantry with 602,441 slices, Tube with 386,429 slices, 6.3 MHU Performex, Octane computer, Software version V4.4, Reformat, Power option, Smart Beam, Smart Prep, 3D, 0.8 second scan, OEM Serviced.

TOSHIBA XVISION – Year 1996.Spiral. Version V5, Xenon Detectors, HV Generator Model TSX-002A 36KVp 120Kvp, MPR, 3-D Imaging, Optical Disk Drive, 85K slices on 3.5MHU X-Ray Tube, 2.3 million Revolutions/Gantry, Phantoms and Patient Accessories

TOSHIBA MODEL XPRESS GX – Year 1996. Spiral / Helical CT Scanner. Gantry with low patient use, Tube: 3.5 mHu with 87,300 slices, Latest Software Version, CT Fluoro, Compact CT Scanner.

TOSHIBA AQUILION QUAD SLICE CT - Year 2000. Gantry: 257,000 scan sec, Tube: 257,000 scan sec, High Voltage Generator, Solid State Multi-Row Detector System, Patient Table, Control Console, Flat Board for RTP, Flat monitor, DICOM DICOM Q/R SCU for Multi, Software: CT Fluoro, Toshiba Workstation with Fly- Through operation, Cardio package included, ECG monitor, Calcium scoring,  

TOSHIBA CT MODEL XVISION EX – Year 1998. Spiral. Compact and Fast CT Scanner with Solid-State Detectors. Tube with 3.5 and approx. 115,000 slices.

TOSHIBA MODEL ASTEION SINGLE SLICE – Year 2000. Spiral. Gantry with 635,000 rotations, 3.5 MHU tube, Real Time Reconstruction, One second reconstruction.

TOSHIBA CT MODEL AQUILLION 16 SLICE – Year 2003. Multislice Spiral / Helical system. Gantry with 850,000+/- slices, Tube: 60,000+/- slices, DICOM Work list, Software version- AQUILION VERSION V2 02ER002 – PROVISION V3.5.1, Double Console, 512 Image Matrix, CXXG-008A Generator.

Siemens Sensation 16 - Year 2003. Multislice 16, Ultra Fast Ceramic Detectors at 672 X 16 and 1344 X 16 Channels; 0.5 Scan Second, Slice Thickness 0.75 to 10mm; Siemens Image Control Computer; Up to 6 Slices/Second; 5.3 mHu X-Ray Tube, 73gb Hard Drive; Generator 60 kW, CT Angiography, CT Simulation, 3-D Package, DICOM 3.0 Interface, System Software and Manuals.

SIEMENS CT MODEL VOLUME ZOOM MULTI SLICE – Year 2001. Quad-Slice. Gantry with 2.1 million rotations, Tube with 255,000 scan seconds. A40, CT Perfusion, Dental software, Leonardo workstation with 3D recon and MIP.

SIEMENS SOMATOM VOLUME ZOOM 4 SLICE CT SCANNER – Year 2002. Gantry: 0.5 Second Rotation, 8 Slices per Second, Lightning UFC, 70 CM Opening, Generator: 60 Kw Generator, 5.3 MHU Tube. Scan Parameters: Scan Time 0.5/0.75/1.0/1.5, Slice Thickness: 0.5/3/5/10 mm, Recon Time: 0.7 Seconds, 80/100s Spiral. Console/Computer/Storage: Windows/sw keys, 53 CM color, Processor, SPARC 10, Syn.SMI 288 MB, Winchester 4 GB, 5.25” MOD, Image Quality: CTDI 13.8 mGy

SIEMENS SOMATOM PLUS 4 POWER - Year 1998. Sub Second 0.75 for a full rotation, 100cm Spiral Length, 80 Seconds Helical Spiral, 1.75 Second Reconstruction Time, DICOM, 2D Post processing, Dynamic Evaluation, Real-time MPR, Maximum Intensity Projection (MIP), UFC-Ultra Fast Ceramic Detector, 1,216,000 Rotations on the Gantry, 112,000 Scan Seconds on a DURA 502 5.3 MHU Tube, VC 10C Software, Duramatic 55kW Generator, CT Angiography, 3D Shaded Surface Display, Cine CT, Bolus Tracking.

SIEMENS CT MODEL SOMATOM PLUS 4 POWER – Year 1997. Sub-Second 0.75 for a Full Rotation, 100cm Spiral Length, 80 Seconds Helical Spiral, 1.75 Second Reconstruction Time, DICOM, 2D Postprocessing, Dynamic Evaluation, Real-time MPR, Maximum Intensity Projection (MIP), UFC-Ultra Fast Ceramic Detector, 3.2 million Rotations on the Gantry, 215,000 Scan Seconds on a DURA 502 5.3MHU Tube, VC 10C Software, Duramatic 55kW Generator, CT Angiography, 3D Shaded Surface Display, Cine CT, Bolus Tracking.

SIEMENS CT MODEL EMOTION SINGLE SLICE – Year 2003. Sub-Second 0.8 Seconds for a full Rotation, 80 Seconds Helical Spiral, 2 Second Image Reconstruction, UFC-Ultra Fast Ceramic Detector, 54,765 Scan Seconds on the Gantry, 3,262 Scan Seconds on the DURA352-MV 3.5MHU Tube, 40kW Generator, VA40C F-SP Software, 2-D Post Processing, Real-time MPR, DICOM, Image Control System(ICS) Computer Platform, Image Reconstruction System(IRS) Computer.

PHILIPS MX 8000 QUAD SLICE SPIRAL CT SCANNER – Year 2002. Multi-Slice acquisition CT Scanner with only 1.2 million scan seconds on the Gantry. 6.5 mHu tube with 255,000 slices +/-. System has CT Fluoro Package, Cardiac Scoring, Virtual Endoscopy, Ultra High Resolution Reconstruction. DICOM 3.0.

PHILIPS/MARCONI MX 8000D DUAL SLICE CT SCANNER - Year 2000. Simultaneous Two Slice Acquisition, 441,264 Total Scan Seconds on Gantry, 6.5 MHU Tube with 23,000 Scan Seconds, 0.75 Second Full 360 degree Sub-Second Scan Mode, 1 Second Image Reconstruction Time, 60 kW High Frequency Generator, 1 mm Slice Thickness, Cardiac Scoring Package, Virtual Endoscopy, 100 Seconds Spiral Scanning, DICOM 3.0 Compliance Including Print, Query/Retrieve, Storage. Ultrahigh Resolution Reconstruction Matrices, Dynamic Focus System, 36 GB Raw Date Storage Memory, 4.1 GB Erasable Optical Disk, UltraImage Image Enhancement Package, Auto Voice, Auto Archive

PHILIPS AV EXPANDER - Year 1998. 1,500,00 Rotations on Gantry, 750,000 Slices on MRC 201 6.5MHU Tube, 60kW Generator, EasyVision Workstation 2.1 Level 5, 100cm Volume Scan, DICOM, Sun Sparc 1.2 GB.

PICKER PQ5000 CT SCANNER - Year 1997. ZAP 100, 645,000 Slices on the Gantry, 252,480 Slices on the Rhino 5.0MHU Tube, CRX 400 Generator, Voxel Q Workstation, 4.6B2 Software, DICOM. Autovoice, Q-Pro, ADS-Advanced Dynamic Scanning, Instaview, MPR-Reconstruction, Hyperlan II, 2.0 Pitch, Exabyte 8mm Tape Drive.

PICKER CT MODEL PQ6000 – Year 1998.Gantry: Approx. 1.7 million slices, Tube: Rhino 5.0 with 252,000 slices. 4800 Detectors, CRX 400 Generator, Voxel Q Workstation, MPR, ADS, Autovoice, Spiral/ZAP180, Injector, Instaview, SVIP, MSSI, 2.0 Pitch, QPRO, QPRO II, Ultra Image, Network Hyperlan II, Profile,  DICOM.

PICKER CT MODEL PQ5000 – Year 1995. Tube with 185,243 slices , 5 mHu; CRX Generator, Software version 4.6.

PICKER CT MODEL PQ 2000 – Year 1994. Tube: 31,261 slices (replaced November 2003), 2.0 MHU Mark 11S Tube; Software Revision 4.6B1, Generator CRX-200, 48 Detectors, ARD.A.S, SBD, AP, BP, EB, SIF, MPM, LAN, Disk Drives 2GB, Tape Drive, Hyperlan 11, DICOM, Options: MPR, ADS, AutoVoice, Spiral ZAP 16.

PICKER/MARCONI ULTRAZ - Year 2000. ZAP Plus Package, 70 Seconds Spiral, Spiral Profile, Spiral Pro, Spiral Intellibeam, 70,000 Slices on a Rhino 5.0MHU Tube, 390,000 Slices on the Gantry, 42kW Generator, Scan Times of 0.6sec (partial), .9, 1, 1.5, 2, 3 and 4 seconds. CTA Support, 4D Angio Support, ESP, Auto Filming, Auto Archive, Auto Voice, ImagePro, Multiplanar Reformatting (MPR), DICOM, UltraImage Package, MIP, 3D Dynamics, Surface CT, ATTACH.

ELSCINT TWIN FLASH - Year 1994. Dual Slice Helical, OmniPro Workstation, 174,000 Slices on 5.0MHU Tube, FLASH Software, 4.4 Software, DICOM, 3D Imaging, Bone Mineral Software.

ELSCINT TWIN FLASH SPIRAL – Year 1996. Gantry: 2.8 million +/- seconds, Tube: Installed January 2004 with 284,562 seconds, Still Installed and Fully Operational,

SHIMADZU CT MODEL SCT 7000 SINGLE SLICE SPIRAL – Year 1997. Gantry: Approx. 1,975,000 rotations, Tube: 5 MHU, Last replaced in March 2003; Patient couch, Console, Power unit, Spiral scan mechanism - max 80 rotation, 3D Reconstruction, MIP, Recordable Auto Voice, Intercom Apparatus, Water Phantom, Phantom mounting tool, Head rest, Patient restraint belt, Optical magnetic disk, Auto tilt, auto film, CT Angio, Pure Power.

SHIMADZU CT MODEL SCT 4000 – Year 1994.Gantry: 156,251 slices, Tube: 156,251 slices, Varian 4.5 MHU Tube, Xenon Detectors, Virtual Endoscopy, 3D, MIP, MPR, CT Fluoro, MOD Storage Device, DICOM Transfer, DICOM Print, DICOM Send.

Top of List

crating.gif (1949 bytes) contactus.gif (1613 bytes) homepage.gif (1577 bytes)

Hablamos Espanol - Falamos Portugues Muito Bem
Nous Parlons Francais - We Praten Nederlands

blue_line.gif (1772 bytes)

United Medical Technologies, Corp.
2196 Andrea Lane
Fort Myers FL 33912 USA
(239) 433-5332 (Voice)
(239) 433-3919 (FAX)
E-Mail:
umtxray@comcast.net

Websites  by
Lade's Internet Service

Copyright ©  United Medical Technologies Corporation.  All rights reserved.